1043 Highland Village Trail — New Construction

Two-Story Single-Family Residence with Finished Basement

Division: Division 3, 6, 7, 9, 15, 16 — Full Structural & Systems

Case Study: 1043 Highland Village Trail, Mableton, GA

Published: 2024-07-15

Author: Ducere Construction Services, Inc. — Licensed General Contractor (GA GCCO006711, FL CBC1263793, NASCLA 404696491)


1043 Highland Village Trail

Mableton, Georgia 30126

New Construction — Two-Story Single-Family Residence with Finished Basement

This Technical Brief documents the structural, civil, and systems engineering deployed at 1043 Highland Village Trail — a 7,395 SF ground-up new construction in Cobb County, Georgia. The residence encompasses 6,288 SF of heated living space across three levels: a 2,052 SF finished basement, a 2,304 SF main floor, and a 1,932 SF upper floor, plus an attached three-car garage.

Every structural element was executed under permit-approved drawings from a licensed architect (Key Designs, Douglasville, GA) and a registered civil engineer (JDM Consultants, LLC, GSWCC #77396). The project was permitted through Cobb County Community Development with a final approved civil set dated April 10, 2024. Retaining wall construction was designed under PE seal by Yong C. Shao, GA PE #26340.


Project Identification

FieldValue
Address1043 Highland Village Trail, Mableton, GA 30126
JurisdictionUnincorporated Cobb County, Georgia
Land LotLot 19, Land Lot 67, District 18
ZoningR-15 — Single Family Residential District
Lot Size17,375 SF (0.399 Acres)
FEMA ZoneZone X — Not in Special Flood Hazard Area
Permit AuthorityCobb County Community Development
Final Approved SetApril 10, 2024
Civil EngineerJDM Consultants, LLC (GSWCC #77396)
ArchitectKey Designs / Shona Griffin, Douglasville, GA
Structural PE (Walls)Yong C. Shao, PE — GA #26340, X&Y Engineering
SurveyorFour Corners Surveying — Ronald T. Godwin, RLS #2696
Owner / GCDucere Construction Services, Inc.
GC LicensesGA GCCO006711 · FL CBC1263793 · NASCLA 404696491

Square Footage & Program

LevelHeated SFDescription
Basement2,052 SF10'-6" ceiling; 8" poured concrete walls w/ 4" furred interior; family room, theater, rec room, bedroom #6, kitchenette, utility
First Floor2,304 SF10' ceiling; owner's suite, kitchen, dining, living, flex room, 3-car garage, covered deck, breezeway, mud room, pantry
Second Floor1,932 SF9' ceiling (18' vaulted loft); bedrooms #3–#5, bonus room, loft, J&J bath, mechanical room, laundry, linen room
**Total Heated****6,288 SF**
Garage (Unheated)682 SF3-car attached — slab on grade; fire separation per IRC R302.6
Patio / Porch / Breezeway425 SFRear covered porch 260 SF + front porch 90 SF + breezeway 75 SF
**Total Gross Area****7,395 SF**

Applicable Codes & Ordinances

CodeEditionAmendments
International Building Code (IBC)2018Georgia Amendments 2020
International Residential Code (IRC)2018Georgia Amendments 2020
International Fire Code (IFC)2018No Georgia Amendments
International Plumbing Code (IPC)2018Georgia Amendments 2020
International Mechanical Code (IMC)2018Georgia Amendments 2020
International Fuel Gas Code (IFGC)2018Georgia Amendments 2020
National Electrical Code (NEC)2020No Georgia Amendments
Int'l Energy Conservation Code (IECC)2015Georgia Supplements & Amendments 2020
Int'l Swimming Pool & Spa Code (ISPSC)2018Georgia Amendments 2020
Cobb County Construction OrdinancesCurrentUnincorporated Cobb County

Civil Engineering & Site Parameters

ParameterValue / Specification
Total Site / Lot Size17,375 SF (0.399 acres) — Lot 19, Highland Village Sub, Plat Book 261, Page 69
Limits of Disturbance10,459 SF (0.24 AC)
Proposed Impervious Area4,767 SF (0.11 AC) — 27.4% lot coverage
Proposed Roof Area2,884 SF
Proposed Driveway / Walkway / Patio1,581 SF
Proposed Pervious Pavers380 SF — Cobb County Water System approved detail
Setbacks (R-15)Front 25' · Side 10' · Rear 30' · Max lot coverage 35%
Stormwater ManagementType C Silt Fence per GSWCC standard; max slope 3:1 in 8" lifts; positive drainage away from building
Specimen Tree Recompense1 × 31" specimen tree removed — $3,410 recompense ($220/2 inches per Cobb County ordinance)
Water / SewerCobb County Water System — 3/4" & 1" meter per Detail 02713-14C; sewer stub-out per Detail 02722-2
BenchmarkFire hydrant top between Lots 3 & 4, Elev. 873.64 (NAVD 88, NAD 83 — RTK-GPS via eGPS Solutions VRS)
GSWCC CertificationGSWCC #77396, Exp. 7/1/2025 — JDM Consultants, LLC
FEMA DeterminationProperty does not lie within a Special Flood Hazard Area — FEMA Map #13067C02171, dated October 5, 2018

Division 3 — Structural Concrete & Foundation System

ComponentSpecification
Foundation SystemCombination — 8" poured concrete walls (below grade) + CMU foundation wall (grade transition) + monolithic slab on grade
Perimeter Footings24" wide × 20" deep concrete footings — all perimeter and load-bearing interior walls
CMU Foundation Wall8" CMU w/ brick masonry veneer on 18" × 18" deep concrete footing
Basement Wall System8" poured concrete wall w/ 4" furred interior; brick masonry veneer above grade on 24" × 20" footing
Slab Construction4" concrete on 6-mil polyethylene vapor barrier on 95% compacted earth; 6×6-10/10 WWF over 4" gravel fill
Concrete Strength3,000 PSI at 28 days (slab & footings) · 4,000 PSI at 28 days (retaining walls — per PE)
Curing ProtocolWet-cured min. 4 days; curing agent (30% solids) applied after wet cure; sawcut twice to 1-1/4" depth within 12 hrs of pour
Soil Bearing CapacityMin. 2,500 PSF — virgin material compacted to 95% Standard Proctor (ASTM D-698)
Thickened Slab LocationsAll load-bearing interior walls, non-bearing walls, and walls bearing ceiling joists without attic or floor above
Garage SeparationMin. 1/2" gypsum board (garage-side walls & ceilings common to house); min. 5/8" Type X gypsum under habitable room

Division 6 — Structural Wood Framing

LevelWall SystemCeiling Height
Basement2×6 @ 16" O.C. (exterior & perimeter)10'-6"
First Floor2×4 @ 16" O.C. standard; 2×6 @ 16" O.C. exterior10'-0"
Second Floor2×4 @ 16" O.C.; 2×6 @ 16" O.C. exterior9'-0" std · 18' vaulted loft · 9' vaulted bonus
Roof — PrimaryAsphalt shingles over 12:12 gable
Roof — SecondaryFlat-pitched EPDM membrane — covered porch decks and garage wing
Roof PitchesPrimary 12:12; secondary 6:12 and 4:12; flat EPDM on covered porch and garage sections
Overhang12" typical eave overhang — all elevations
Stairs — Basement18 stairs · 7-1/2" risers · 10" treads · (3) 2×12 stringers min. · 1/2" plywood risers glued & screwed
Stairs — Main17 stairs · 7-1/2" risers · 10" treads · open railing
Guardrail / Baluster4" max. clear spacing (IRC R312.1.3); 36" ht. first floor; 42" ht. upper floors; 1" diameter balusters

Division 7 / 9 — Exterior Envelope & Finish Package

ElementSpecification
Primary CladdingVertical board & batten siding — all four elevations
Secondary CladdingSmooth & seamless HardiPanel board siding (fiber cement — James Hardie or approved equal)
Masonry AccentBrick masonry veneer — base course, first floor banding, and garage wing
Stone AccentStone masonry veneer — upper gable peak, front elevation feature
Horizontal Band12" architectural band at floor-to-floor transition — all elevations
Roof (Primary)Asphalt shingles over 12:12 main gable
Roof (Secondary)Flat-pitched EPDM membrane — covered porch decks and garage wing
Columns6" PT wood columns (porch and covered deck)
WindowsDouble-hung and fixed glass — 3060, 4070, 5070, 6070 series; egress per IRC R310 in all bedrooms
Garage DoorsAvante 3-panel 24" (16080 opening) · Avante 2-panel 24" (8080 opening)
Ext. DoorsTempered glass panel — 3068, 4080, 6080 series; all exterior glazing tempered per IRC R308

Division 15 / 16 — MEP & Electrical Systems

SystemSpecification
Water ServiceCobb County Water System — 3/4" & 1" meter; residential driveway per Detail 116R
Sanitary SewerPublic sewer stub-out — Cobb County Water System Detail 02722-2; 4" SDR 35 PVC
Mechanical CodeIMC 2018 w/ Georgia Amendments 2020
Fuel GasIFGC 2018 w/ Georgia Amendments 2020; 48" gas range/hood (kitchen); ventless fireplace on non-combustible hearth
Electrical CodeNEC 2020 — no Georgia amendments
Smoke DetectorsHardwired and interconnected — each sleeping room and outside each sleeping area on every story (IRC R314)
CO DetectorsImmediately outside each sleeping room — hardwired and interconnected (IRC R315)
GFCI ProtectionAll wet locations, garages, exterior, bathrooms, kitchen circuits per NEC 210.8
Special SystemsAudio/video control panel, CAT5/CAT5+TV jacks, intercom, thermostat, door chime — per Sheet A-7
Emergency EgressAll bedrooms — min. 5.7 SF net clear, 24" min. clear height, 20" min. clear width (IRC R310)
Attic / Crawl AccessAttic: min. 22"×30" (IRC R807); crawl space: min. 16" H × 24" W (IRC R408.4)

Permit Drawing Index

SheetTitleDate
C1Civil Cover Sheet — Site plan, vicinity map, FEMA map, applicable codes4/10/2024
C2Site Plan — Lot coverage, setbacks, utility connections, specimen tree recompense4/9/2024 rev.
C3Grading Plan — Pervious paver detail, erosion/sedimentation controls, planting notes4/9/2024 rev.
SurveyBoundary Survey — Four Corners Surveying, GA RLS #26962/8/2024
A-1Architectural Cover Sheet — Scope, codes, square footage calculation, drawing index7/15/2024
A-2Front & Left Elevations (scale 1/4"=1')7/15/2024
A-3Right & Rear Elevations (scale 1/4"=1')7/15/2024
A-4Basement Floor Plan — 2,052 SF; door/window schedule7/15/2024
A-5First Floor Plan — 2,304 SF; door/window schedule; general notes7/15/2024
A-6Second Floor Plan — 1,932 SF; door/window schedule7/15/2024
A-7Electrical Plan — All three levels; electrical/data/audio legend7/15/2024
A-8Foundation Plan — Footing schedule, thickened slab locations7/15/2024
A-9–A-12Framing Plans (Floor, Ceiling, Roof) + Sections & Details7/15/2024
SW-1.0–SW-4.0Retaining Wall Construction Plans — PE-Sealed (see companion brief)3/28/2024

Ducere Construction Services, Inc. · 5925 Mulberry Street, Suite 101 · Austell, GA 30168 · GA GCCO006711 · FL CBC1263793 · NASCLA 404696491 · (404) 565-0631

All data from permit-approved construction documents, Cobb County, 2024.